McAlpine Soakaway

In stock
Product Code
100005201
Features: 110x300mm x 1¼"/1½" (32mm) pipe top and side inlet connections. For use with limestone chippings. Receives discharge from a condensing boiler. ...Read more

DISCLAIMER

This product qualifies for next working day delivery provided it is in stock and your order is placed by 1pm Monday to Thursday. For full T&C's read our Delivery Information.

Your Price
£32.27 £26.89
 
Add to Project List

Select branch to check stock

Select postcode to see availability

Features:

  • 110x300mm x 1¼"/1½" (32mm) pipe top and side inlet connections.
  • For use with limestone chippings.
  • Receives discharge from a condensing boiler.
  • For external use only.
  • 19/23mm x 32mm solvent weld fitting provided to increase size of discharge pipe before it passes through external wall.

Installation Guidelines on Condensate Discharge:

  • The condensate from the boiler should, where possible, be discharged into the internal drainage of the household drainage system.
  • Internal condensate discharge pipework must be a minimum diameter of 19mm (which is generally viewed as 22mm OD) and must be of corrosion-free plastic pipe.
  • The discharge pipework must ’fall’ at least 45mm per metre away from the boiler and take the shortest possible route to the discharge point or waste system.
  • It is recommended if the condensate pipework has to be taken externally to the termination pipe, the pipework should be no less than 32mm in diameter - The external pipework should be as short in length as possible and should be protected with waterproof lagging from extreme weather conditions.
  • Where the boiler already has an internal trap, no other trap should be installed as this will cause the boiler trap to malfunction.
  • Waste pipe fittings should be kept to a minimum as the discharge flow should be as free as possible.
  • If the discharge pipe is terminated into a gully, the pipe should be cut below the grating cover and above the water level - The pipe end entering the gully should be cut at 45Degree.

External Installation to a Soakaway:

  • When installing a soakaway the ground conditions must be taken into consideration - It is recommended that the soakaway is not installed near any service pipework such as water or electrical mains cables and the installation of the soakaway should be a minimum of 500mm away from the building.
  • The McAlpine soakaway should be installed in a hole depth of approximately 400mm minimum x 200mm in diameter.
  • The soakaway should then be placed in the hole with the cut holes in the soakaway facing away from the foundations of the building.
  • The soakaway should then be filled with 10mm limestone chippings.

Soakaway Installation:

  • The condensate pipework may terminate above or below ground level - If above ground the condensate pipe must be protected with a waterproof lagging.
  • The pipe end entering the soakaway must be at a depth of 25mm minimum and the end of the pipe cut at 45Degree.
  • It is recommended that the soakaway is inspected during the annual service of the boiler.

Technical data:

  • Conforms to - BS 6798:2009 and Building Regulations Approved Document H
  • Brand - McAlpine

  • Manufacturer Code
    370SOAK1GR
  • Brand
    McAlpine
  • Brand
    McAlpine
Check for Delivery

Returns

This product can be returned if returned unopened, unused and in a fully resalable condition, including the original packaging.

Click here for the MP Moran return policy

If no Data and Safety sheets are visible here please send an email request to [email protected]